Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Adv Radiat Oncol ; 8(6): 101277, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38047223

RESUMO

Purpose: In irradiating the prostate and pelvic lymph node regions, registration based on bony structures matches the pelvic lymph node regions but not necessarily the prostate position, and it is important to identify factors that influence prostate displacement. Therefore, we investigated factors influencing prostate displacement during volumetric modulated arc therapy after single-fraction high-dose-rate brachytherapy (HDR-BT) for prostate cancer and the trends in displacement for each fraction. Methods and Materials: Seventy patients who underwent pelvic volumetric modulated arc therapy of 46 Gy in the prone position 15 days after 13 Gy HDR-BT were included. Prostate displacement relative to bony structures was calculated using cone beam computed tomography. Systematic error (SE) and random error (RE) were evaluated in the right-left (RL), craniocaudal (CC), and anteroposterior (AP) directions. The association with clinical and anatomic factors on the planning computed tomography or magnetic resonance imaging was analyzed. Prostate volume change (PVC) was defined as the volume change at 2 days after HDR-BT. Displacement trends were individually examined from the first to 23rd fractions. Results: The mean SE in the RL, CC, and AP directions was -0.01 mm, -2.34 mm, and -0.47 mm, respectively. The root mean square of the RE in the RL, CC, and AP directions was 0.44 mm, 1.14 mm, and 1.10 mm, respectively. SE in the CC direction was independently associated with bladder volume (P = .021, t statistic = 2.352) and PVC (P < .001, t statistic = -8.526). SE in the AP direction was independently associated with bladder volume (P = .013, t statistic = -2.553), PVC (P < .001, t statistic = 5.477), and rectal mean area (P = .008, t statistic = 2.743). RE in the CC direction was independently associated with smoking (P = .035). RE in the AP direction was associated with PVC (P = .043). Gradual displacement caudally and posteriorly occurred during the irradiation period. Conclusions: Anatomic characteristics of the bladder, rectum, and prostate predict SE. Smoking and PVC predict RE. In particular, whether PVC is ≥140% affects setting internal margins.

2.
Radiol Phys Technol ; 16(2): 227-234, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36947352

RESUMO

Treatment planning systems that use the Monte Carlo algorithm can calculate the dose to the medium (Dm) in non-water-equivalent tissues such as bones. However, Dm cannot be verified using actual measurements; therefore, it is necessary to develop tissue-equivalent dosimeters. In this study, we developed a bone-equivalent polymer gel dosimeter (BPGD) that can measure the dose absorbed by the bone and investigated its sensitivity. The BPGDs were prepared by adding 3.0 mol of calcium hydrogen phosphate dihydrate as a component of bone to an improved dose-sensitive polyacrylamide gelatin and tetrakis hydroxymethyl phosphonium chloride (iPAGAT). One day after preparation, the BPGDs were irradiated with a field size of 15 × 15 cm2 using a 10 MV X-ray beam to evaluate the dose sensitivity, dose-rate dependence, and dose-integration dependence. One day after dose exposure, the BPGDs were scanned using a 0.4 T MRI APERTO Eterna (Hitachi, Tokyo, Japan) to obtain R2 values. The difference between the R2 values of 6 Gy and 0 Gy was up to 5 s-1, and the R2 curve plateaued in the high-dose region. Moreover, the BPGD did not depend on the integration of the dose and dose rates. Therefore, the BPGDs that we developed can determine the radiation dose to bones.


Assuntos
Algoritmos , Dosímetros de Radiação , Japão , Método de Monte Carlo , Polímeros , Radiometria , Géis
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(11): 1349-1357, 2022 Nov 20.
Artigo em Japonês | MEDLINE | ID: mdl-36328484

RESUMO

PURPOSE: The purpose of this study was to evaluate the accuracy of incident air kerma (Ka,r) and air kerma-area product (PKA) displayed on over-couch-type X-ray fluoroscopic systems by comparing them with the measured values. METHODS: An ionizing chamber was placed at the patient entrance reference point to measure the Ka,r. The PKA was calculated by multiplying the Ka,r by the irradiation area. These measured values were compared with the displayed values. RESULTS: The differences between measured and displayed Ka,r and PKA were less than ±35%, which was the criteria of the Japanese Industrial Standards (JIS). However, the accuracy of the displayed values differed depending on the manufacturer and the device. CONCLUSION: Although no error exceeding the JIS criteria was observed, it is necessary to understand the characteristics of the X-ray fluoroscopic systems related to displayed dose and to manage the systems by performing dose measurements periodically.


Assuntos
Indústrias , Humanos , Raios X
4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 77(10): 1180-1185, 2021.
Artigo em Japonês | MEDLINE | ID: mdl-34670925

RESUMO

The purpose of this study was to establish a simple measurement method to verify the accuracy of incident air kerma (Ka, r) and air kerma area product (PKA) displayed on an over-couch-type X-ray fluoroscopy system. A dosimeter was located at the patient entrance reference point, and the irradiation field size was set to 10×10 cm. A lead plate was placed on the couchtop to protect the image receptor, and the duration of fluoroscopy was set to 1 min. The Ka, r was measured with the proposed method and the Japanese Industrial Standards (JIS) method on three X-ray fluoroscopy units of different manufactures. The effect of backscattered X-rays from the lead plate was calculated using Monte Carlo methods. The errors of the displayed Ka, r and PKA to the measured Ka, r and PKA with our proposed method were calculated. There was no significant difference in the measured Ka, r between the proposed method and the JIS method in all units. The effect of backscattered X-ray was ≤0.5%. The errors of displayed Ka, r and PKA to those measured were in the range of 3.4 to 15.7% and -4.1 to 20.3%, respectively, which met the tolerance for accuracy of ±35% in accordance with the JIS method. We found that our proposed method was simple and that the accuracy of measured values was comparable to that of the JIS method.


Assuntos
Dosímetros de Radiação , Fluoroscopia , Humanos , Método de Monte Carlo , Radiografia , Raios X
6.
J Appl Clin Med Phys ; 22(1): 76-91, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33270985

RESUMO

PURPOSE: To investigate the effect of an integral quality monitor (IQM; iRT Systems GmbH, Koblenz, Germany) on 4, 6, 10, and 6-MV flattening filter-free (FFF) photon beams. METHODS: We assessed surface dose, PDD20,10 , TPR20,10 , PDD curves, inline and crossline profiles, transmission factor, and output factor with and without the IQM. PDD, transmission factor, and output factor were measured for square fields of 3, 5, 10, 15, 20, 25, and 30 cm and profiles were performed for square fields of 3, 5, 10, 20, and 30 cm at 5-, 10-, and 30-cm depth. RESULTS: The differences in surface dose of all energies for square fields of 3, 5, 10, 15, 20, and 25 cm were within 3.7% whereas for a square field of 30 cm, they were 4.6%, 6.8%, 6.7%, and 8.7% for 4-MV, 6-MV, 6-MV-FFF, and 10-MV, respectively. Differences in PDD20,10 , TPR20,10 , PDD, profiles, and output factors were within ±1%. Local and global gamma values (2%/2 mm) were below 1 for PDD beyond dmax and inline/crossline profiles in the central beam region, respectively. The gamma passing rates (10% threshold) for PDD curves and profiles were above 95% at 2%/2 mm. The transmission factors for 4-MV, 6-MV, 6-MV-FFF, and 10-MV for field sizes from 3 × 3 to 30 × 30 cm2 were 0.926-0.933, 0.937-0.941, 0.937-0.939, and 0.949-0.953, respectively. CONCLUSIONS: The influence of the IQM on the beam quality (in particular 4-MV X-ray has not verified before) was tested and introduced a slight beam perturbation at the surface and build-up region and the edge of the crossline/inline profiles. To use IQM in pre- and intra-treatment quality assurance, a tray factor should be put into treatment planning systems for the dose calculation for the 4-, 6-, 10-, and 6-MV flattening filter-free photon beams to compensate the beam attenuation of the IQM detector.


Assuntos
Aceleradores de Partículas , Radiometria , Humanos , Fótons
7.
J Appl Clin Med Phys ; 22(2): 58-68, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33369014

RESUMO

The Catalyst HD (C-RAD Positioning AB, Uppsala, Sweden) optical surface imaging (OSI) system is able to manage interfractional patient positioning, intrafractional motion monitoring, and non-contact respiratory gating without x-ray exposure for radiation therapy. In recent years, a novel high-precision surface registration algorithm for stereotactic radiosurgery (SRS algorithm) has been released. This study aimed to evaluate the technical performance of the OSI system using rigid phantoms, by comparing the conventional and SRS algorithms. To determine the system's technical performance, isocenter displacements were calculated by surface image registration via the OSI system using head, thorax, and pelvis rigid phantoms. The reproducibility of positioning was evaluated by the mean value calculated by repeating the registration 10 times, without moving each phantom. The accuracy of positioning was evaluated by the mean value of the residual error, where the 10 offset values given to each phantom were subtracted from the isocenter displacement values. The stability of motion monitoring was evaluated by measuring isocenter drift during 20 min and averaging it over 10 measurements. For the head phantom, all tests were compared with the mask types and algorithms. As a result, for all sites and both algorithms, the reproducibility, accuracy, and stability for translation and rotation were <0.1 mm and <0.1°, <1.0 mm and <1.0°, and <0.1 mm and <0.1°, respectively. In particular, the SRS algorithm had a small absolute error and standard deviation of calculated isocenter displacement, and a significantly higher reproducibility and accuracy than the conventional algorithm (P < 0.01). There was no difference in the stability between the algorithms (P = 0.0280). The SRS algorithm was found to be suitable for the treatment of rigid body sites with less deformation and small area, such as the head and face.


Assuntos
Radiocirurgia , Algoritmos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Suécia
8.
Artigo em Japonês | MEDLINE | ID: mdl-32684559

RESUMO

PURPOSE: The aim of this study was to analyze improvement prediction on contour deformation accuracy using deformable image registration (DIR) results compared to rigid image registration (RIR) results. METHOD: Radiotherapy plans for 31 cases (seven head and neck cases, 10 chest cases, six abdomen cases and eight female pelvis cases) from the privately open database for DIR were used. These cases used at least two radiotherapy plans, and registration was performed using two plans, not only for one case but also for different cases. The DIR and RIR were performed using the DIR software MIM Maestro (MIM software Inc., Cleveland, USA). The registration results for the following organs were analyzed: eye balls, optic nerves, brain stem, spinal cord and right and left parotid glands for head and neck; right and left lungs for chest; liver and right and left kidneys for abdomen; and rectum and bladder for pelvis. Dice similarity coefficient (DSC) for the organs was calculated from the results of RIR and DIR. The improvement in the DSC was observed. RESULTS AND DISCUSSION: DIR improved the DSC values by more than 0.2 for simple shapes, well-defined boundaries and large volumes such as eye balls, brain stem, lungs and liver. The minimum DSC for these organs was approximately 0.7. The improvement in DSC for the organs eye balls, brain stem, lungs and liver had ceiling values 0.95, 0.90, 1.0 and 1.0, respectively. DSC for the spinal cord, parotid gland, bladder and kidney also improved by DIR compared to RIR; however, DIR could not improve the DSC value for rectum compared to RIR because of a large difference in the position, shape and size due to stool and gas.


Assuntos
Processamento de Imagem Assistida por Computador , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Feminino , Cabeça , Pescoço
9.
Phys Med ; 74: 83-91, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32446173

RESUMO

PURPOSE: This study aimed to measure the eye lens doses received by physicians and other medical staff participating in non-vascular imaging and interventional radiology procedures in Japan. MATERIAL AND METHODS: From October 2014 to March 2017, 34 physicians and 29 other medical staff engaged in non-vascular imaging and interventional radiology procedures at 18 Japanese medical facilities. These professionals wore radioprotective lead glasses equipped with small, optically stimulated luminescence dosimeters and additional personal dosimeters at the neck during a 1-month monitoring period. The Hp(3) and the Hp(10) and Hp(0.07) were obtained from these devices, respectively. The monthly Hp(3), Hp(10), and Hp(0.07) for each physician and other medical staff member were then rescaled to a 12-month period to enable comparisons with the revised occupational equivalent dose limit for the eye lens. RESULTS: Among physicians, the average annual Hp(3) values measured by the small luminescence dosimeters on radioprotective glasses were 25.5 ± 38.3 mSv/y (range: 0.4-166.8 mSv/y) and 9.3 ± 16.6 mSv/y (range: 0.3-82.4 mSv/y) on the left and right sides, respectively. The corresponding values for other medical staff were 3.7 ± 3.1 mSv/y (range: 0.4-10.4 mSv/y) and 3.2 ± 2.7 mSv/y (range: 0.5-11.5 mSv/y), respectively. CONCLUSIONS: The eye lens doses incurred by physicians and other medical staff who engaged in non-vascular imaging and interventional radiology procedures in Japan were provided. Physicians should wear radioprotective glasses and use additional radioprotective devices to reduce the amount of eye lens doses they receive.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Cristalino/efeitos da radiação , Corpo Clínico , Imagem Molecular , Exposição Ocupacional/análise , Doses de Radiação , Radiologia Intervencionista , Humanos , Japão , Exposição à Radiação/análise
11.
Phys Imaging Radiat Oncol ; 6: 77-82, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33458393

RESUMO

BACKGROUND AND PURPOSE: In adaptive radiotherapy, deformable image registration (DIR) is used to propagate delineations of tumors and organs into a new therapy plan and to calculate the accumulated total dose. Many DIR accuracy metrics have been proposed. An alternative proposed here could be a local uncertainty (LU) metric for DIR results. MATERIALS AND METHODS: The LU represented the uncertainty of each DIR position and was focused on deformation evaluation in uniformly-dense regions. Four cases demonstrated LU calculations: two head and neck cancer cases, a lung cancer case, and a prostate cancer case. Each underwent two CT examinations for radiotherapy planning. RESULTS: LU maps were calculated from each DIR of the clinical cases. Reduced fat regions had LUs of 4.6 ±â€¯0.9 mm, 4.8 ±â€¯1.0 mm, and 4.5 ±â€¯0.7 mm, while the shrunken left parotid gland had a LU of 4.1 ±â€¯0.8 mm and the shrunken lung tumor had a LU of 3.7 ±â€¯0.7 mm. The bowels in the pelvic region had a LU of 10.2 ±â€¯3.7 mm. LU histograms for the cases were similar and 99% of the voxels had a LU < 3 mm. CONCLUSIONS: LU is a new uncertainty metric for DIR that was demonstrated for clinical cases. It had a tolerance of <3 mm.

12.
Radiol Phys Technol ; 10(2): 213-226, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28025782

RESUMO

The goal of this study is to develop a more appropriate shielding calculation method for computed tomography (CT) in comparison with the Japanese conventional (JC) method and the National Council on Radiation Protection and Measurements (NCRP)-dose length product (DLP) method. Scattered dose distributions were measured in a CT room with 18 scanners (16 scanners in the case of the JC method) for one week during routine clinical use. The radiation doses were calculated for the same period using the JC and NCRP-DLP methods. The mean (NCRP-DLP-calculated dose)/(measured dose) ratios in each direction ranged from 1.7 ± 0.6 to 55 ± 24 (mean ± standard deviation). The NCRP-DLP method underestimated the dose at 3.4% in fewer shielding directions without the gantry and a subject, and the minimum (NCRP-DLP-calculated dose)/(measured dose) ratio was 0.6. The reduction factors were 0.036 ± 0.014 and 0.24 ± 0.061 for the gantry and couch directions, respectively. The (JC-calculated dose)/(measured dose) ratios ranged from 11 ± 8.7 to 404 ± 340. The air kerma scatter factor κ is expected to be twice as high as that calculated with the NCRP-DLP method and the reduction factors are expected to be 0.1 and 0.4 for the gantry and couch directions, respectively. We, therefore, propose a more appropriate method, the Japanese-DLP method, which resolves the issues of possible underestimation of the scattered radiation and overestimation of the reduction factors in the gantry and couch directions.


Assuntos
Doses de Radiação , Proteção Radiológica , Espalhamento de Radiação , Tomografia Computadorizada por Raios X
13.
BJR Case Rep ; 3(1): 20160087, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-30363308

RESUMO

A technique for multiple breath-hold segmented volumetric modulated arc therapy (VMAT) has been proposed under real-time fluoroscopic image guidance with implanted fiducial markers. Fiducial markers were embedded as close as possible to a tumour and the patient was asked to breathe in slowly under fluoroscopy. Immediately after the marker positions on the fluoroscopic image moved inside the planned marker contours transferred from a digitally reconstructed radiographic image at each gantry start angle, the patient was asked to hold their breath and a segmented VMAT beam was delivered. During beam delivery, the breath-hold status was continuously monitored by viewing a pointer in a breath monitoring system, Abches (Apex Medical, Tokyo, Japan), with the aid of a video camera installed in the treatment room. As long as the pointer stayed still, the segmented VMAT delivery continued for a preset period of 15-30 s, depending on the breath-hold capability of each patient. As soon as each segmented delivery was completed, the beam interrupt button was pushed; subsequently, the patient was asked to breathe freely. Because the preset breath-hold period was determined in order for each patient to hold their breath without fail, an intermediate beam interrupt due to breath-hold failure during the segmented beam delivery was not observed. This procedure was repeated until all the segmented VMAT beams were delivered. A case of pancreatic cancer is reported here as a preliminary study. The proposed technique may be clinically advantageous for treating tumours that move with respiration, including pancreatic cancer, lung tumour and other abdominal cancers.

14.
Radiol Phys Technol ; 9(2): 178-86, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26873139

RESUMO

In volumetric modulated arc therapy (VMAT) for prostate cancer, a positional and rotational error correction is performed according to the position and angle of the prostate. The correction often involves body leaning, and there is concern regarding variation in the dose distribution. Our purpose in this study was to evaluate the impact of body pitch rotation on the dose distribution regarding VMAT. Treatment plans were obtained retrospectively from eight patients with prostate cancer. The body in the computed tomography images for the original VMAT plan was shifted to create VMAT plans with virtual pitch angle errors of ±1.5° and ±3°. Dose distributions for the tilted plans were recalculated with use of the same beam arrangement as that used for the original VMAT plan. The mean value of the maximum dose differences in the dose distributions between the original VMAT plan and the tilted plans was 2.98 ± 0.96 %. The value of the homogeneity index for the planning target volume (PTV) had an increasing trend according to the pitch angle error, and the values of the D 95 for the PTV and D 2ml, V 50, V 60, and V 70 for the rectum had decreasing trends (p < 0.05). However, there was no correlation between differences in these indexes and the maximum dose difference. The pitch angle error caused by body leaning had little effect on the dose distribution; in contrast, the pitch angle correction reduced the effects of organ displacement and improved these indexes. Thus, the pitch angle setup error in VMAT for prostate cancer should be corrected.


Assuntos
Neoplasias da Próstata/radioterapia , Doses de Radiação , Erros de Configuração em Radioterapia , Radioterapia de Intensidade Modulada/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
16.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(5): 445-52, 2014 May.
Artigo em Japonês | MEDLINE | ID: mdl-24858289

RESUMO

The purpose of our study was to evaluate radiation dose and beam quality in photon-counting digital mammography (PCDM) and compare them with those in a full-field digital mammography (FFDM) unit. Dose variation in the X-ray tube axis direction, aluminum half-value layer, average glandular and skin doses, and contrast-to-noise ratio (CNR) were evaluated for the PCDM and FFDM units. In PCDM, the dose variation in the X-ray tube axis direction was greater than that in FFDM. At a tube voltage of 28 kV, the first half-value layers were 0.407 mmAl for PCDM, 0.357 mmAl for FFDM with a molybdenum target and molybdenum filter (Mo/Mo), and 0.579 mmAl for FFDM with a tungsten target and rhodium filter (W/Rh). The average glandular doses with 45-mm-equivalent breast thickness were 0.723 mGy for the PCDM, 1.55 mGy for the FFDM with Mo/Mo in low-dose mode, and 0.835 mGy for the FFDM with W/Rh in low-dose mode. In PCDM, the skin dose was equivalent to or lower than that in FFDM. The CNR was 2.65±0.04, 2.35±0.04, and 2.52±0.03 for the PCDM, FFDM with Mo/Mo, and that with W/Rh, respectively. The CNR for PCDM was significantly higher than that for FFDM (p<0.001). It is therefore possible to reduce the radiation dose to the patient by using a PCDM unit while maintaining a significantly higher CNR than with the FFDM unit.


Assuntos
Mamografia/instrumentação , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Imagens de Fantasmas , Fótons , Controle de Qualidade
17.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(3): 191-8, 2014 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-24647055

RESUMO

Digital chest phantoms continue to play a significant role in optimizing imaging parameters for chest X-ray examinations. The purpose of this study was to develop a digital chest phantom for studies on energy subtraction techniques under ideal conditions without image noise. Computed tomography (CT) images from the LIDC (Lung Image Database Consortium) were employed to develop a digital chest phantom. The method consisted of the following four steps: 1) segmentation of the lung and bone regions on CT images; 2) creation of simulated nodules; 3) transformation to attenuation coefficient maps from the segmented images; and 4) projection from attenuation coefficient maps. To evaluate the usefulness of digital chest phantoms, we determined the contrast of the simulated nodules in projection images of the digital chest phantom using high and low X-ray energies, soft tissue images obtained by energy subtraction, and "gold standard" images of the soft tissues. Using our method, the lung and bone regions were segmented on the original CT images. The contrast of simulated nodules in soft tissue images obtained by energy subtraction closely matched that obtained using the gold standard images. We thus conclude that it is possible to carry out simulation studies based on energy subtraction techniques using the created digital chest phantoms. Our method is potentially useful for performing simulation studies for optimizing the imaging parameters in chest X-ray examinations.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas/tendências , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/tendências , Radiografia Torácica/instrumentação , Radiografia Torácica/tendências , Técnica de Subtração/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/tendências
18.
Jpn J Radiol ; 31(5): 357-63, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23526485

RESUMO

PURPOSE: To evaluate the reproducibility of diaphragm position in our new breath-holding radiotherapy for abdominal tumors using image-guided radiation therapy (IGRT) and a voluntary breath-holding device, Abches. MATERIALS AND METHODS: Patients treated with abdominal tumors using IGRT with Abches were enrolled. Twenty patients without dementia or severe lung disease were analyzed. Each fraction of all patients was set up with kV cone-beam CT with reference to the vertebral bodies. Before daily treatment, electronic portal imaging device (EPID) images of the diaphragm at breath-holding exhale phase were acquired. The difference in the diaphragm position relative to the vertebral body was analyzed by comparing EPID images and the digitally reconstructed radiograph of the planning CT. We evaluated the reproducibility of two axes: superior-inferior (S-I) and right-left (R-L) with the EPID measurements. RESULTS: The 443 irradiation data sets were analyzed. The interfractional reproducibility of the diaphragm relative to vertebral bodies was 1.7 ± 1.4 mm in the S-I and 1.4 ± 1.2 mm in the R-L direction. CONCLUSION: This technique has good interfractional reproducibility and visibility of the diaphragm during irradiation. Its use is feasible in the routine clinical setting and irradiation.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/radioterapia , Suspensão da Respiração , Diafragma/diagnóstico por imagem , Radioterapia Guiada por Imagem/métodos , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada de Feixe Cônico , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/instrumentação , Reprodutibilidade dos Testes , Coluna Vertebral/diagnóstico por imagem
19.
Artigo em Japonês | MEDLINE | ID: mdl-22104230

RESUMO

Recently about 90% of radiographs have been taken by the digital radiographic system in Japan, but the exposure dose of the patients are about ten-times different among the systems. We understood it by a surveytaken in 2007. We studied the visual evaluation with varying exposure doses using the image phantom of the lumber AP, lumber lateral and hip AP. Additionally we measured quantum efficiency (DQE) of the digital systems. We also studied the exposure index (EI) of IEC standard to see whether it is able to be the sensitivity index among the digital systems. DQE in 1.0 cycle/mm of CR, FPD (GOS), FPD (CsI, a-Se) became 0.2-0.25, 0.3, 0.5, respectively. Our results display that the dose reduction is relative to DQE. The visual evaluation results also show that dose reduction is possible among the systems. From these results, we are able to reduce the exposure dose of the patients at the clinical site. We also suggest that we manage the exposure dose using the E.I of the IEC standard.


Assuntos
Melhoria de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Relação Dose-Resposta à Radiação , Japão , Imagens de Fantasmas , Teoria Quântica , Intensificação de Imagem Radiográfica/instrumentação
20.
Artigo em Japonês | MEDLINE | ID: mdl-22104236

RESUMO

The purpose of this study was to optimize X-ray conditions for full spine X-ray examinations in slot-scan digital radiography (SSDR). Follow-up of spinal deformities, such as scoliosis, typically involves many radiographs of the patient throughout childhood and adolescence. The Radiation doses for the full spine X-ray examination should be minimized. Recently, SSDR has been introduced for full spine as well as lower extremity examinations. This system utilizes slot scanning geometry to acquire the radiographic images. X-ray energy characteristics of direct amorphous Selenium (a-Se) digital fluoroscopy and short time X-ray tube loads of this system were investigated. Orthopedists evaluated the irradiation time for full spine radiographs in various conditions using an observer study. Patient doses were measured with radiophotoluminescence glass dosimeters, which were implanted in various tissue and organ positions within an anthropomorphic phantom. In the optimization of conditions for SSDR, patient doses are reduced by approximately 60% compared to default setting.


Assuntos
Melhoria de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Coluna Vertebral/diagnóstico por imagem , Humanos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...